Home     About Us     Global Network     Info Centre     News     Contact Us

Home >> Fuel & Oil Testing >> Applications >> Slow Speed Diesels


Density Meter


Density Meter FG-K1-300-KW

The Kittiwake Density Meter is suitable for diesel & residual fuel oils. Use it to confirm the quantity of fuel delivered, verify that the correct grade of fuel has been delivered, estimate the combustion performance (CCAI), correct viscosity in cP to cSt.

The Density Meter can be purchased as a stand-alone kit, supplied in its own case, or as part of a more extensive suite of testing equipment in the Fuel and Lube Oil Test Cabinet , or Power Plant Laboratory .

The Kittiwake Density Meter has been proven to be as accurate as laboratory methods. Click this link to view an independant report from a leading analysis laboratory.

Hydrometers

The Density Meter measures density using a hydrometer dropped in warmed oil. Most oil can be measured at 50ºC but for very viscous oils the units can be set to warm to 70ºC.

There is a calculator feature, which allows the reading to be adjusted to show Density at 15 ºC in a vacuum. If the viscosity is known in Censtistokes or Centipoise the calculator will display the CCAI.

The Density Meter uses Hydrometers to measure the density of marine fuels corrected to kg/m3 at 15oC. With this information and the viscosity of the fuel, the Density Meter can determine:

Mass of fuel delivered

Calorific value

Anticipated combustion performance (CCAI)



Hydrometers are available in three ranges. One of each is supplied with the Density Meter.

Note: The Density Meter must not be used for heating any liquids other than diesel or residual fuel oils. It is not suitable for use with any fuels with a low flash point temperature (e.g. gasoline).



Click here to download the CCAI Test in action


Specifications


Accuracy:

Typically within +/- 0.1% (800-1010 kg/m³)

Calculations:

Density at 15°C in vacuo, centiPoise to centiStokes

Correlation:

ASTM D1298 IP160

Dimensions:

18 x 23 x 10cm

Power:

110/240 VAC (autoselected)

Range:

800 to 1010 kg/m³ @ 15°C

Temperature:

50°C and 70°C

Test Time:

Heating from 15°C 10 mins, Repeat test maximum 30 seconds

Weight:

2.20kg


Want to know more?
Contact Kittiwake here

For other related products see also:
Cloud Point Detectors
Compatibility Tester
Flashpoint Tester
Heated Viscometer
Oil Test Cabinet
Oil Test Centre
Pour Point
Power Plant Laboratory
Unheated Viscometer


Download PDF of Density Meter  Yellow Arrow


To view the document you will need Adobe Acrobat Reader installed on your system. If you do not have it click here to proceed to Adobe's website to download it.



Spare Hydrometers
Range, Relative Density
Part Number
0.80 - 1.01 @ 15°C
AS-K3-014-KW
0.85 - 0.95 @ 15°C
AS-K3-015-KW
0.90 - 1.01 @ 15°C
AS-K3-016-KW