• Automatic flashpoint results in seconds for fuels or lubes.

  • Important safety & quality assurance measure under SOLAS convention.

  • Used in BioDiesel to detect contamination from low flashpoint methanol
Quick Contact
CAPTCHA
This question is for testing whether you are a human visitor and to prevent automated spam submissions.
Image CAPTCHA
Enter the characters shown in the image.

Related Products

Flashpoint Tester

Flashpoint TesterProduct Code: FG-K16909-KW

Flash point is the temperature at which the vapours of a fuel ignite when a test flame is applied. The flash point for all fuels to be used in bulk onboard vessels is set at 60°C minimum (SOLAS* agreement). ISO8217 Grade DMX, a special low cloud point gasoil, may only be stored onboard in drums because of its < 60°C flash point. The fuel flash point is an important quality and safety assurance measure. The flash point of biodiesel is used to detect contamination from low flashpoint methanol.  Flashpoint is used in lube oils as an indication of fuel oil contamination.

The Flashpoint Tester / Analyzer is easy to use, completing a fuel flash/no-flash test in less than two minutes. It will determine the flash point of a lube sample within a temperature range of 0 to 300°C in typically 8 minutes and boasts the following core features:

  • Digital display showing test parameters, instrument status, and the flashpoint test result.
  • Audible alarm when flashpoint test is completed and action is required from the operator.
  • Automatic flash detector enhances repeatability and reduces the chance of mis-interpretation.
  • Small sample size - 2 or 4ml.

*SOLAS - Safety of Life At Sea - International Convention.
For shipping reasons, a butane refill cartridge is not supplied and so will need to be purchased locally. 


 Specifications

Cup Material:Aluminium
Ramp Rate:2°C / min ramp
Sample Size:2 - 4 ml
Size (HxWxD)::26 x 28 x 26cm
Temp Range:Ambient 0 to 300°C
Test Duration, Rapid Equilibrium Mode:1 minute below 100°C, 2 minutes above 100°C, or user determined 1 to 99 minutes
Test Modes:Rapid Equilibrium and Ramp, 1 to 99 minutes.
Voltage:110/120V or 220/240V, 50/60Hz (switchable), 12Vdc with optional adaptor
Weight:4 kg

Ordering Information

Part Number Description
FG-K16909-KWElectronic Flashpoint Tester

Bunker Fuel

Latest News

How a healthy & viable shipping industry can help to reduce greenhouse gas emissions
Global prosperity is built on shipping and trade.  The world as we know it would be unthinkable wit... Read More...
Parker Kittiwake Announces Launch of Two New Water Glycol Condition Monitoring Tools
This week sees the launch of Parker Kittiwake’s latest online condition monitoring tools, the icou... Read More...
Diane and Nicola’s Cromer Crab Walk for Hospice Appeal Fund
If you’re travelling through Norfolk on 11th May you might just spot a couple of giant shellfish w... Read More...